Low-temperature ozone sterilizer. Rapid disinfection and rapid sterilization of: surgical instruments, orthopedic and traumatological instruments and equipment, endoscopic instruments and equipment, heat-intolerant medical products – endoprostheses, catheters, anesthesia tubes, etc.
Models CK-16, CK-36, CK-40, CK-85, CK-250

Orion CK-16 ozone sterilizer
- Working volume: 16 l
- Sterilization cycle duration: 30 min
- Temperature in working compartment (max): 40–45 °C
- Chamber internal dimensions (W/H/D): 30х20х27 cm
- Power consumption: 70 W
- Weight: 11 kg
For sterilization of low volumes of instruments, applicable in dentistry, microsurgery, ophthalmology, outpatient surgery, including for sterilization of instruments containing optical part.

Orion CK-36 ozone sterilizer
- Working volume: 36 l
- Sterilization cycle duration: 35 min
- Temperature in working compartment (max): 40–45 °C
- Chamber internal dimensions (W/H/D): 35х25х35 cm
- Power consumption: 70 W
- Weight: 16 kg
In surgery, dentistry, microsurgery; in outpatient surgery for sterilization, including for instruments containing optical parts, gynecological instruments, endoprostheses, catheters, anesthesia tubes, masks

Orion CK-40 ozone sterilizer
- Working volume: 40 l
- Sterilization cycle duration: 40 min
- Temperature in working compartment (max): 40–45 °C
- Chamber internal dimensions (W/H/D): 30х20х57 cm
- Power consumption: 70 W
- Weight: 16 kg
Sterilization of endoscopic instruments, including those containing optical parts, orthopedic and traumatological instruments, as well as equipment, heat-intolerant medical products – en

Orion CK-85 ozone sterilizer
- Working volume: 85 l
- Sterilization cycle duration: 45 min
- Temperature in working compartment (max): 40–45 °C
- Chamber internal dimensions (W/H/D): 70х35х35 cm
- Power consumption: 70 W
- Weight: 22 kg
Sterilization of endoscopic instruments, including those containing optical parts, orthopedic and traumatological instruments and equipment, including drills, heat-intolerant medical products – endoprostheses, catheters, anesthesia tubes, etc.

Orion CK-250 ozone sterilizer
- Working volume: 250 l
- Sterilization cycle duration: 70 min
- Temperature in working compartment (max): 40–45 °C
- Chamber internal dimensions (W/H/D): 100х50х50 cm
- Power consumption: 70 W
- Weight: 70 kg
High volume for sterilization of endoscopic instruments, including those containing optical parts, orthopedic and traumatological instruments and equipment, heat-intolerant medical products – endoprostheses, catheters, etc.
Advantages of "Orion-SIARM" sterilizers
Rapid disinfection and rapid sterilization of:
- Surgical instruments, orthopedic and traumatological instruments and equipment, endoscopic instruments and equipment, heat-intolerant medical products – endoprostheses, catheters, anesthesia tubes, etc.
- Low-temperature mode jf less than 45 СО Alows to sterilize heat-intolerant products and materials.
- STERILIZATION OF OPTICAL PARTS, POLYMER AND GLASS PRODUCTS, AS WELL AS OTHER HEAT-INTOLERANT PRODUCTS.
- Gentle entline impact on the absence of high pressure and high temperatures in the chamber.
- SHORT EXPOSURE TIME THE COMPLETE STERILIZATION CYCLE TAKES FROM 30 MINUTES FOR CK-16L STERILIZER TO 70 MINUTES FOR CK-250L STERILIZER
- MAXIMUM SAFETY FOR MEDICAL PERSONNEL IS ENSURED BY AIRTIGHTNESS, RELIABILITY AND EASE OF OPERATION.
- DOES NOT REQUIRE AERATION, IS NOT TOXIC AS A RESULT OF DECOMPOSITION OZONE MOLECULE O3 FORMS OXYGEN O2.
- CHAMBER TRANSPARENCY ALLOWS TO OBSERVE INSTRUMENT INSERTION AND REMOVAL WITHIN THE OPERATION SHIFT.
- PORTABILITY ENSURED BY LOW WEIGHT AND LACK OF REQUIREMENT TO CONNECT THE UNIT TO THE OXYGEN SUPPLY NETWORK OF THE MEDICAL INSTITUTION.
- LOW POWER CONSUMPTION (70 W) AND NO CONSUMABLES (APART FROM THE OZONE DESTRUCTOR REQUIRING REPLACEMENT ONCE A YEAR).
Advanced ozone technology maximizes efficiency, is cost-effective and environmentally friendly.
Pros and cons of different sterilization methods comparison table
Sterilization and Destruction cycle duration
During the Destruction cycle, complete deactivation of ozone and its transition from a three-atomic molecule (O3) to a two-atomic molecule (O2) – normal oxygen – occurs. Thus, the use of Orion sterilizer is an effective, waste-free, environmentally friendly, safe for personnel and the environment method of sterilization.
The following are also indisputable advantages typical for all modifications of Orion Sterilizers:
|
|